Provides a visual reference of remaining fluid level in a tank / reservoir used with the Dyna-Star HP or HF pump. Low Level Indicators equipped with a user supplied alarm will also provide an audible and/or visual notification of a low fluid level. For professional use only.
Installing Low Level Indicator Warnings 1. Disconnect Dyna-Star pump from main power source. See the Dyna-Star HP and HF Pump Instruction manual 2. If unit has already been in service, relieve pressure for additional warnings. (see Pressure Relief procedure, page 2).
Page 3
6. Remove screws (e) and washers (f) holding Dyna-Star Pump to reservoir cover (b) and remove 8. (If previously installed) remove follower plate from pump from cover (F . 4). inside reservoir. 9. Determine the correct cable length to use for your pump reservoir.
Page 4
11. Remove one of the screws (k) from the follower plate (m) (F . 7). 12. Install screw (k) through the hole (n) in the cable bracket (p) located at the end of the low level cable (j) and then through the screw hole (r) in the follower plate (m) (F .
Page 5
Installation 16. Slide pump down-tube through hole in the center of 17. Replace screws (e) and washers (f) and wrench the reservoir cover (b) and hole in the center of the tighten securely (F . 12). follower plate (m) as shown in F .
Page 6
PINS 1 and 3 of the DIN, Form “A” Field Wireable Adapter. See F . 14. . 14 2. Connect Dyna-Star pump to main power source. 3. Start system following pump start up procedure included in the Dyna-Star HP or HF Pump Manual provided with your system. 332515F...
Page 7
Low Level Visual Indication Sight Glass Low Level Visual Indication Sight Glass sight Red (R) sight Green (G) glass glass Green (G) . 15 . 17 Normal Level Mark (F . 15) - Red rod is completely covered by the green tube (G) and no red is visible in Low Level Mark (F .
Page 8
Dip Stick Installation Dip Stick Installation 1. Remove plug (a) from cover (b). Discard plug, you will not reuse it (F . 18). . 18 . 19 2. Slide dipstick through hole (aa) in cover (b) and into reservoir (F .
Page 9
Low Level Indicator Technical Data Low Level Indicator Technical Data Low level sensor switch Normally open sensor switch, closes upon low level Operating temperature range -50°F to 150°F (-45°C - 65°C) Electrical Ratings Switching Power 10 Watt Max. Switching Current 0.4A-Max.