Gearboxes - Schulte GX-130 Operator's Manual

Table of Contents

Advertisement

Gearboxes

Procedure for refilling right angle gearbox:
1. Park unit on a level surface and lower the
wings. Install the center lock pin and block the
unit to prevent falling or rolling.
2. From under the cutter, remove the blade
carrier to access the drain plug.
3. Remove the drain plug and drain out oil.
4. Reinstall the drain plug and blade carrier.
5. Remove the dipstick.
6. Fill gearbox until oil level reaches halfway up
the sight glass. Capacity is approximately 4.2
liters (4.4 qt.). Do not screw in dipstick when
checking oil level.
7. Reinstall vent plug/dipstick. Dispose of old oil
in accordance with the local regulations.
Replace oil in gearboxes after the first 50 hours of
operation then yearly.
Check gearbox oil level frequently. Steady loss of
oil will indicate damaged seals, which should be
replaced immediately to prevent ruining the
gearbox.
GX-130 04/23
© 2023 Alamo Group Inc.
MAINTENANCE
Maintenance Section 5-8

Advertisement

Table of Contents
loading

Table of Contents