Lubrication; Gearboxes - Schulte GX-150 Operator's Manual

Rotary cutter
Table of Contents

Advertisement

LUBRICATION

Gearboxes

Procedure for refilling right angle gearboxes:
1. Park unit on a level surface and lower the
wings. Install the center lock pin and block the
unit to prevent falling or rolling.
2. From under the cutter, remove the blade carrier
to access the drain plug.
3. Remove the drain plug and drain out oil.
4. Reinstall the drain plug and blade carrier.
5. Remove the dipstick.
6. Fill gearbox until oil level reaches halfway up
the sight glass. Capacity is approximately 4.2
liters (4.4 qt). Do not screw in dipstick when
checking oil level.
7. Reinstall vent plug/ dipstick. Dispose of old oil in
accordance with the local regulations.
Replace oil in gearboxes after the first 50 hours of
operation then yearly.
Check gearbox oil level frequently. Steady loss of oil
will indicate damaged seals, which should be
replaced immediately to prevent ruining the
gearbox.