Maintenance (Continued)
Reassembly
1.
Place the Frame Assembly (E) face down and place the Pre-
Filter (D) down inside of it.
2.
Note the airflow direction listed on the Main Filter (C). The
arrow should be pointing toward the fans when installed.
16 X 25 X 3
AIR
FLOW
3.
Push the Main Filter (C) into the Frame Assembly (E) up
against the Pre-Filter (D) while taking care not to touch the
filter media or damage the Main Filter's frame.
14
Oneida Air Systems, Inc.
4.
FILTER INSTALLED
MONTH
DAY
YEAR
5.
Align the Frame Assembly (E) and the Fan Assembly (B),
making sure that the notches on the sides of the Frame
Assembly engage the stop-studs on the sides of the Fan
Assembly.
Reattach the four Thumb Screws onto the Frame Assembly
(E) to securely close the unit.