Oneida Air Systems Pro 1500 Owner's Manual

Oneida Air Systems Pro 1500 Owner's Manual

Hide thumbs Also See for Pro 1500:

Advertisement

Pro 1500 / Pro 2000
Dust Collector
Owner's Manual
Oneida Air Systems, Inc. 1001 West Fayette St., Syracuse, NY 13204
Phone 1.800.732.4065 315.476.5151 Fax 315.476.5044 www.oneida-air.com
Shown with
optional Stand.
Models may vary slightly
in appearance.
9_11

Advertisement

Table of Contents
loading

Summary of Contents for Oneida Air Systems Pro 1500

  • Page 1 Pro 1500 / Pro 2000 Dust Collector 9_11 Owner’s Manual Shown with optional Stand. Models may vary slightly in appearance. Oneida Air Systems, Inc. 1001 West Fayette St., Syracuse, NY 13204 Phone 1.800.732.4065 315.476.5151 Fax 315.476.5044 www.oneida-air.com...
  • Page 2: Table Of Contents

    Thank You for Choosing an Oneida Air Systems Product! OAS manufactures and sells dust collection equipment only. Our qualifi ed technicians and sales staff are available 7:30am - 6:00pm EST Mon. - Thurs. and 7:30am - 5:00pm EST Fri. to answer any questions concerning OAS products and dust collection.
  • Page 3: System Start-Up Information

    Do not operate Fan / Blower unless Fan Housing is attached to Cyclone body and Dust Drum is in place. Dust Drum and Cyclone must be in place and sealed or motor will overheat! Warning If amperage is too high - shut down immediately! See Troubleshooting section. Pro 1500 / 2000 © O.A.S. 2010...
  • Page 4: Confi Gurations

    GE Certifi ed (H-12) HEPA media. MERV 16+ rated. Pat. Pend. Flame Guard Arrestor Wall Bracket Included Square to Round Inlet Included Filter Effi ciency Gauge Included Silencer Do Not Remove Pat. Pending 11/313,728 Shown with optional Stand. Included Magnetic Starter Pro 1500 / 2000 © O.A.S. 2010...
  • Page 5: General Specifi Cations & Fan Performance Curve

    Pro Series (5hp) 2000 Dust Collector - 3 Ph. XXK200003H Pro 1500 w/o Filter Pro 2000 w/o Filter *Oneida reserves the right to change or modify specs and system appearance without notice. Actual system appearance may vary. Pro 1500 / 2000 © O.A.S. 2010...
  • Page 6: Dimensions

    IV. Dimensions For Minimum Mounting Heights w/ 39” Filter *Dimensions subject to slight variation in manufacturing. 7” / 8” 94.00 / 94.00 97.5 36” 6.00 Pro 1500 / 2000 © O.A.S. 2010...
  • Page 7: General Assembly

    V. General Assembly - (Pro 1500) XXK150001 1 Phase / XXK150003 3 Phase - (Pro 2000) XXK200001 1 Phase / XXK200003 3 Phase Filter Grounding Wire - FGA000000 3. Cyclone Barrel - SXI002109 / SCI002309 4. Cyclone Cone - SCX012109 / SCX002309 (8) Spring Clips 5a.
  • Page 8: General Assembly Instructions

    Otherwise you will not get the seal needed for complete dust collection! Gasket material goes outside of clip holes Clip Gasket on top and bottom of Material fan housing. Washer Bolt Collector Barrel Pro 1500 / 2000 © O.A.S. 2010...
  • Page 9: General Assembly Instructions

    Lift Motor & Plate onto Fan/Blower housing and bolt together in proper direction. Note: For preseparation there must be an air tight seal between cyclone and dust container. Dust bin must be located vertically under cyclone. Material drops down by gravity. Pro 1500 / 2000 © O.A.S. 2010...
  • Page 10: Bracket Assembly

    Use three 3/8” bolts (included) with washers & lock washers to secure the fan. See Fig. 4. 5. Attach tightly with bolts. 16 1/4” Put at 69” if you are using a 55 gal. drum. Pro 1500 / 2000 © O.A.S. 2010...
  • Page 11: Stand Assembly

    Use (2) 5/16” x 1” bolts, (2) 5/16” flat washers and (2) 5/16” whiz nuts on each gusset. Stand Leg Set 35 Gal. (4) - SXX000035 Stand Leg Set 55 Gal. (4) - SXX000055 Pro 1500 / 2000 © O.A.S. 2010...
  • Page 12: Drum Assembly

    J Hook pipe can be purchased. 7. Attach the fi lter dust bin to the bottom of the fi lter with the J hooks making sure that the seal is tight. Pro 1500 / 2000 © O.A.S. 2010...
  • Page 13: Filter Maintenance

    Fan wheel must rotate counter-clockwise if looking down on fan housing. Use 12 gauge cord for the fan / blowers. Caution: Rotating Fan Blades! Keep objects clear of outlet. Lubrication: See pg. 15 for schedule and specifi cations. Pro 1500 / 2000 © O.A.S. 2010...
  • Page 14: Directions For Cleaning Filter

    Note: This Dust Collector is pre- Always use a licensed, professional electrician. wired at the factory and need only be plugged into a NEMA 6-20R dedicated electrical receptacle. Follow wiring diagram on motor. #hp single phase only. Pro 1500 / 2000 © O.A.S. 2010...
  • Page 15: Filter Effi Ciency Gauge Mounting Instructions

    4. When the gauge rises to 3”, it’s time to clean your fi lter(s). After many cleaning cycles, a fi lter’s pressure will rise after each cleaning. An older fi lter does not get as clean as a new fi lter. Pro 1500 / 2000 © O.A.S. 2010...
  • Page 16: Fan Motor Maintenance

    Wall Mounting Magnetic Starter Fastener Captive Fastener Remove front cover. Fasten screws through mounting bracket into mounting surface. (Screw needs to be smaller than Captive Fastener.) Attach Starter cover and tighten Captive Fasteners. Pro 1500 / 2000 © O.A.S. 2010...
  • Page 17: Remote Wiring Diagram

    Retrofi t (Wiring) of Wireless Remote into 220V OAS Import Magnetic Starters: AMI020000 / AMI030000 Remote is mounted inside starter top cover by using double-sided tape (Supplied). Contactor Overload Adjustment Dial Remove this factory installed red wire! Pro 1500 / 2000 © O.A.S. 2010...
  • Page 18: Accessories

    Can be used with 35 and 55 gal. barrels. Must be wired into your system. Drum Liner - Plastic Bag Hold-Down ABX000035 / ABX000055 Holds plastic bag in drum for easy removal and disposal. Pro 1500 / 2000 © O.A.S. 2010...
  • Page 19: Troubleshooting

    - Make sure clamp around cyclone is tight and sealed with silicone. Excessive Vibration Caused By: Loose mounting bolts. Excessive system pressure or restriction of air due to closed blast gates. Accumulation of foreign material on the fan wheel. Inadequate support structure. Pro 1500 / 2000 © O.A.S. 2010...
  • Page 20: Fire Hazards - Read Before Installing System

    - Electrically ground all equipment and ducting. Static sparks can ignite wood dust. (Avoid using PVC drainpipe). - Don’t allow accumulation of layers of fi ne dust on horizontal surfaces. (Especially overhead lights, electrical boxes, and fuse panels which can ignite dust). Pro 1500 / 2000 © O.A.S. 2010...
  • Page 21 Returned Goods Policy Buyer must inform Oneida Air Systems of any shortage or damage, by so noting in writing, on the freight delivery bill prior to signing to indicate receipt of shipment. All claims covered under the limited warranty, are subject to inspection and investigation by Oneida Air Systems. Oneida Air Systems reserves the right to inspect and investigate all returned products before Buyer’s claim is settled.

This manual is also suitable for:

Pro 2000

Table of Contents