Table of Contents

Advertisement

GO-5000M-PGE-1 | GO-5000M-PGE-UV-1 | User Manual (Ver. 1.0)

Timed Mode

This mode allows a single image frame to be captured with a preset exposure time by using the
external trigger. Additional settings determine if the trigger pulse can be accepted during the exposure
period.
Primary settings to use this mode
Trigger Mode = ON
l
Trigger Source: Opt IN (6p connector)
l
Trigger Option: Off
l
Optical Filter Selector: 10μs
l
Readout Mode
Full
ROI 2/3 (Height=1365)
ROI 1/2 (Height=1024)
ROI 1/4 (Height=512)
ROI 1/8 (Height=256)
1/2V Binning
t1
10μs (Min)
Minimum Trigger Interval
44.843 ms
29.962 ms
22.532 ms
11.377 ms
5.8 ms
22.532 ms
t2
61 μs
- 61 -
Main Functions
t3
5L to 6L