Descriptions of Index Table Parameters

Command
Sequence ROI Index
Index 1 ~ 10
Sequence ROI Frame
1 ~ 255
Count
Index 1 ~ 10
Sequence ROI Next
Index
Off
Sequence ROI Width
16 ~ 2560*
Sequence ROI Height
1 ~ 2048*
0 ~ 2560*- [Sequence ROI
Sequence ROI Offset X
Width]
0 ~ 2048* – [Sequence ROI
Sequence ROI Offset Y
Height]
Sequence ROI Gain
100 ~ 1600
Sequence ROI
10 ~ 8000000
Exposure Time
Sequence ROI H
1, 2, 4 (3 is disabled)
Binning
Sequence ROI V
1, 2, 4 (3 is disabled)
Binning
Sequence ROI LUT
0  (Disable)
enable
1  (Enable)
Sequence ROI Black
-256 ~ 255
Level
Sequence Repetition
1 ~ 255
Command Sequence
Index 1 ~ 10
Index
Current Sequence
Index 1 ~ 10
Index
Sequence LUT Mode
Gamma LUT
Sequence Reset
No (EXE command)
Note: *If the binning mode is used, the maximum value is changed.
Parameter
Select an index to be set
<Set to each Index>
Set fame number for display per a frame
<Set to each Index>
<Used for Trigger Sequence Mode>
Set the index to be active at the next
Off: Stop a sequence operation at the current index.
<Set to each Index>
Set the width value
<Set to each Index>
Set the height value
<Set to each Index>
Set the offset value.
<Set to each Index>
Set the offset Y.
<Set to each index>
Set the gain value.
<Set to each Index>
Set the exposure time value.
<Set the same value for all Indexes>
Set the H Binning value.
<Set the same value for all Indexes>
Set the V Binning value.
<Set the same value for all Indexes>
Set the disable or enable of LUT. If it is set to enable, the function is selected in the
Sequence LUT mode.
<Set to each index>
Set the black level value.
<For Trigger Sequence Mode>
Set the repeat number of the sequence.
<For Command Sequence Mode> Set the performed index.
<READ only>
Refer to the current Sequence Index.
Set the function if Sequence ROI LUT is set to enable.
Set the value on Gamma or LUT control.
Reset the Sequence Index to 0.
At the same time, the Frame Count is also initialized.
Description
- 68 -
Main Functions