JAI GO-5000M-PGE-1 User Manual page 50

Table of Contents

Advertisement

GO-5000M-PGE-1 | GO-5000M-PGE-UV-1 | User Manual (Ver. 1.0)
Multi-Frame
In this mode, the AcquisitionStart command captures the number of frames which are specified by
AcquisitionFrameCount.
Normal Multi-Frame Operation
1. AcquisitionStart command is input
2. AcquisitionActive becomes "TRUE" (accepts capture)
3. Output N frames as specified by AcquisitionFrameCount
4. AcquisitionActive becomes "FALSE". Then the output stops. (See the following diagram)
Note: This figure is if the trigger is set to ON. When the trigger is OFF, FrameActive becomes True
at the same timing of AcquisitionActive.
Forcing Acquisition to Stop
While AcquisitionActive is "TRUE", if AcquisitionStop or AcquisitionAbort is initiated, AcquisitionActive
becomes "FALSE" (stop capturing). Once the operation is set to "FALSE", the internal FrameCount is
reset. However, if AcquisitionStop command is initiated during image output period, AcquisitionActive
becomes "FALSE" (stop capturing) after image output is completed. Once, AcquisitionActive becomes
"FALSE", the internal count is reset.
Acquisition Frame Count:
Can be set in the range of 1 to 255.
- 50 -
Main Functions

Advertisement

Table of Contents
loading

This manual is also suitable for:

Go-5000m-pge-uv-1

Table of Contents