Diagnostics And Troubleshooting; Error Displays Of The Operating State Leds - Leuze electronic DDLS 538 S2 Series Original Operating Instructions

Optical data transmission for ethercat - version f3/f4
Table of Contents

Advertisement

Diagnostics and troubleshooting

8
Diagnostics and troubleshooting
What to do in case of failure?
The LED displays in the control panel provide information about possible warnings or errors (see chapter
3.3.1 "Indicators and operational controls in the control panel"). Using the LED displays, you can determine
the causes and initiate rectification measures.
NOTICE
Contact Leuze subsidiary/customer service!
Ä If the specified measures are not successful, contact the responsible Leuze subsidiary or
Leuze customer service (see chapter 10 "Service and support").
8.1

Error displays of the operating state LEDs

Tab. 8.1:
PWR LED displays – Causes and measures
LED
Color
PWR ---
Red
Red
Tab. 8.2:
TMP LED displays - Causes and measures
LED
Color
TMP
Orange Continuous
Red
Note
Data transmission remains active if above or below the operating temperature.
An operating hour counter is started internally that records the operating time outside of the specified
operating temperature.
In this case, the laser diode is excluded from guarantee services.
Leuze electronic GmbH + Co. KG
State
possible causes
OFF
No supply voltage
Hardware error
Flashing
Ambient temperature too high
Warning message set:
temperature warning
Continuous
Device error
light
State
possible causes
The operating temperature is
light
above or below the specified
range by up to 5 °C.
Continuous
The operating temperature is
light
above or below the specified
range by more than 5 °C.
Measures
Check supply voltage.
Contact Leuze customer service (see
chapter 10 "Service and support").
Initiate measures for lowering the ambient
temperature.
Contact Leuze customer service (see
chapter 10 "Service and support").
Measures
Check ambient temperature.
• Initiate measures for lowering the am-
Check ambient temperature.
• Initiate measures for lowering the am-
DDLS 538 ... S2 ...
bient temperature.
bient temperature.