Starting Up The Device; Setting The Operating Mode - Leuze electronic DDLS 538 S2 Series Original Operating Instructions

Optical data transmission for ethercat - version f3/f4
Table of Contents

Advertisement

Starting up the device

6
Starting up the device
6.1

Setting the operating mode

The active operating mode is displayed on the control panel to the left next to the operating mode selector
switch [MODE] via LEDs (see chapter 3.3.1 "Indicators and operational controls in the control panel").
1
AUT – Automatic
2
MAN – Manual
3
ADJ – Adjust
4
LAS – Alignment laser for mounting support
5
LLC – Link Loss Counter
6
MAS – EtherCAT configuration specifying the position at which the device is installed – master side or slave
side
7
MODE – Operating mode selector switch
Fig. 6.1:
Operating mode selector switch and operating mode LEDs
The operating mode selector switch [MODE] is used to switch between the operating modes of the device:
Tab. 6.1:
Operating modes / EtherCAT configuration
Operating mode
AUT
Automatic
MAN
Manual
Leuze electronic GmbH + Co. KG
6
Description
Standard operating mode for data transmission. When the supply voltage is applied,
the device starts in the AUT operating mode.
Note:
Operating modes that were active before the device was switched off are no longer
active after the device is switched back on.
Operating mode for fine adjustment of the devices via SHA (see chapter 6.2.2 "Fine
adjustment with the single-handed adjustment (SHA) process").
Data transmission switches off as soon as no green LEDs in the SIGNAL QUALITY
indicator illuminate.
Note:
The AUT LED switches off if the MAN operating mode is activated.
DDLS 538 ... S2 ...