Bus (Bus Input, Ethercat) - Leuze electronic DDLS 538 S2 Series Original Operating Instructions

Optical data transmission for ethercat - version f3/f4
Table of Contents

Advertisement

Electrical connection
NOTICE
Maximum input current!
The maximum input current of the switching input is 8 mA.
NOTICE
Maximum loading of the switching output!
The switching output is protected against short-circuit, overcurrent, overvoltage, excess temper-
ature and transients.
Ä Do not load the switching output with more than 60 mA at +18 ... +30 VDC.
5.3

BUS (bus input, EtherCAT)

4-pin, M12 socket (D-coded) for connecting to BUS (EtherCAT connection).
2
3
1
4
Fig. 5.3:
Pin assignments for BUS connection
Tab. 5.2:
BUS pin assignments
Pin
1
2
3
4
(M12-socket
thread)
Connection cables: see chapter 12.2 "Cables accessories"
NOTICE
The device supports a transmission rate of 100 Mbit/s in full duplex mode as well as auto-cross-
over.
NOTICE
The entire interconnection cable must be shielded.
The shielding connection must be at the same potential at both ends of the data line. This
serves to prevent potential equalization currents over the shield and possible interference cou-
pling through compensating currents.
Ä Use at least a CAT 5 cable for the connection.
Leuze electronic GmbH + Co. KG
Designation
Assignment
TD+
Transmit Data + (transmitter)
RD+
Receive Data + (receiver)
TD-
Transmit Data - (transmitter)
RD-
Receive Data - (receiver)
FE
Connection cable shield
The shield of the connection cable is on the thread of the M12 socket.
The thread of the M12 socket is part of the metallic housing. The hous-
ing is at the potential of the functional earth via pin 5 of the POWER
connector plug.
DDLS 538 ... S2 ...