Indicators In The Optics Area - Leuze electronic DDLS 538 S2 Series Original Operating Instructions

Optical data transmission for ethercat - version f3/f4
Table of Contents

Advertisement

Device description
3.3.2

Indicators in the optics area

For simple, quick diagnosis, the device is equipped with a STATUS LED in the optics area.
The STATUS LED enables a quick summary diagnosis of the operating state of the device.
• The STATUS LED summarizes the displays of the individual LEDs of the control panel in a single indi-
cator.
• The STATUS LED illuminates very brightly and can also be seen from a relatively long distance.
1
1
STATUS LED
Fig. 3.6:
STATUS LED in the optics area
Tab. 3.4:
Meaning of the STATUS LED display
LED
Color
STATUS
Green
LED
Green
---
Leuze electronic GmbH + Co. KG
State
Description
Continuous light
Not a warning or error message.
Flashing
There is/are warning message(s) (see chapter 8.2 "Error dis-
plays and STATUS LED for remote diagnosis"):
• SIGNAL QUALITY indicator without green LED in operating
modes AUT (Automatic), MAN (Manual), ADJ (Adjust)
• Temperature, warning or error (TMP)
• Laser pre-failure (LSR)
• Link Loss Counter has triggered (LLC)
Data transmission is active.
OFF
• No supply voltage.
• SIGNAL QUALITY indicator shows only red LEDs.
• The LINK and LINK/ACT LEDs are off.
• The transmitter is deactivated (see chapter 8.2 "Error dis-
plays and STATUS LED for remote diagnosis").
• MAS EtherCAT configuration is activated on both devices
or MAS EtherCAT configuration is deactivated on both de-
vices.