Mounting
NOTICE
You will achieve greater flexibility during basic installation and fine adjustment if you mount the
devices on C profile rails.
Ä Detach the contour of the optical window from the drilling template along the perforation.
Ä Affix the removed drilling template to the optical window of the mobile device using the supplied self-ad-
hesive labels.
Ä Switch on the alignment laser of the stationary device. Activate the LAS (Alignment laser) operating
mode to switch on the alignment laser (see chapter 6.1 "Setting the operating mode").
Ä Move the mobile device on the lifting axis in manual operation to maximum distance.
Ä Align the stationary device using the alignment screws (see chapter 3.1.1 "Device construction",
point 11 and point 12) and, if necessary, using the C-profile rails.
ð The target spot of the alignment laser must be in the center of the drilling template on the mobile
device.
Ä Move the mobile device on the lifting axis in manual operation to minimum distance.
ð The target spot of the alignment laser must not extend beyond the outer ring of the drilling template
on the mobile device.
ð If necessary, realign the stationary device.
Ä Switch off the alignment laser of the stationary device. Activate the AUT (Automatic) operating mode to
switch off the alignment laser (see chapter 6.1 "Setting the operating mode").
Ä Affix the detached drilling template to the optical window of the stationary device using the supplied
self-adhesive labels.
Ä Switch on the alignment laser of the mobile device. Activate the LAS (Alignment laser) operating mode
to switch on the alignment laser (see chapter 6.1 "Setting the operating mode").
Ä Move the mobile device on the lifting axis in manual operation to maximum distance.
Ä Align the mobile device using the alignment screws (see chapter 3.1.1 "Device construction", point 11
and point 12) and, if necessary, using the C-profile rails.
ð The target spot of the alignment laser must be in the center of the drilling template on the stationary
device.
Ä Move the mobile device on the lifting axis in manual operation to minimum distance.
ð The target spot of the alignment laser must not extend beyond the outer ring of the drilling template
on the stationary device.
ð If necessary, realign the mobile device.
Ä Switch off the alignment laser of the mobile device. Activate the AUT (Automatic) operating mode to
switch off the alignment laser (see chapter 6.1 "Setting the operating mode").
Ä Remove the drilling template from the stationary device.
ð This concludes the mounting of the devices in the lifting axis.
Further procedure:
• Perform the fine adjustment for the lifting axis (see chapter 6.2 "Fine adjustment").
4.3

Mounting without alignment laser

Ä Observe the mounting instructions (see chapter 4.1 "Mounting instructions").
NOTICE
You will achieve greater flexibility during basic installation and fine adjustment if you mount the