Efco SIRIUS 700 Operators Instruction Book page 39

Table of Contents

Advertisement

Error message
CN099: Recov escape
CN104: Battery over
heating
CN110: Blade motor over
heating
CN119: R-Bumper
deflected
CN120: L-Bumper
deflected
CN125: Bumper escape
CN128: Recov Impossible
CN129: Blocked WL
CN130: Blocked WR
Possible cause
Error cannot be cleared automatically
The robot has moved outside the
operating area
Battery overheating – battery
temperature has exceeded 60°; battery
cannot discharge
Robot lawnmower motor is
overheating, temperature > 80°C.
The robot has collided with an
obstacle and is unable to break free for
reasons of safety, e.g. collisions that
occur too close to the base station.
When reversing after colliding with an
obstacle the robot has moved outside
the operating area.
Collision with an obstacle or escape
from circuit -> reversing impossible,
the robot is unable to break free.
Left-hand drive wheel jammed
Right-hand drive wheel jammed
Solution
Clear the error manually
Return the robot lawnmower to the base station.
Electronic controller performs emergency shut-down
procedure. Do not position the robot on the base
station. Switch off the robot and allow the battery to
cool down.
Switch off the robot and allow it to cool down. If the
problem recurs have the robot checked by an
authorized service centre
Remove the obstacle and reset the error message.
The housing is jammed or the bumper is faulty; remove
the obstacle
Remove the obstacle and make sure the robot housing
is correctly positioned
Remove obstruction
Remove obstruction
77

Advertisement

Table of Contents
loading

Table of Contents