Installation Data - Space-Ray FUSION Series Installation & Operation Instructions

Infrared radiant poultry tube heater, single and two stage push through system positive pressure
Table of Contents

Advertisement

IGNITION MODULE DIAGNOSTICS
Flame Fault
If at any time the main valve fails to close completely and maintains a flame, the full time flame sense circuit will
detect it and energize the combustion blower. Should the main valve later close completely removing the flame
signal, the combustion blower will power off following the post purge period.
Fault Conditions
Error Mode
Internal Control Failure
Air Flow Fault
Gas valve failure (stuck open)
Ignition Lockout
The LED located on the ignition module will flash ON
for ¼ second, then OFF for ¼ second during a fault
condition.
The pause between fault codes is 3
seconds.
22.0)

INSTALLATION DATA

Date of
Installation:
Serial
No.
Model:
FUSION
Form 43343100
April 2022 A
LED Indication
Steady On
1 Flash
2 Flashes
3 Flashes
# of Heaters in
System:
-55-