C. LOW VOLTAGE (24V) 3 WAY MANUAL SWITCH CONNECTIONS – MULTIPLE HEATERS
13.3)

RECOMMENDED THERMOSTAT SENSOR LOCATION

The thermostat sensor should be located approximately 10ft from side of the heater as shown in Figure 1 and at
distances from burner box as shown in chart of Figure 2 below. Ideally this should also be located between the
feed and drink lines. Avoid locating the sensor in a direct draft such as in front of a fan or between the fan and a
door. The result can cause overrunning of the heater and excess fuel consumption.