8. Check to ensure that the hardware is completely closed and the band is seated on the reaction block and
interference pins as illustrated above.
9. Once all the heater body sections are attached, make sure that the heater system is level. If it is not, slight
adjustments can be made using the turnbuckles. (See Section 8.0)
Important: NEVER reuse a coupling.. Always install a new coupling only and torque as per instructions above and
the diagrams below.
9.2)

INSERTING TURBULATORS

1. Assemble the turbulators together by interlocking the slotted end portions. Slide these into the last tube
section until they are flush with the tube end. Note: Refer to the table below for quantities of turbulators
required for each heater model.
MODEL
2 Ft. Turbulator Sections
FUS 60
FUS 70
FUS 80
FUS 90
Form 43343100