RC4080 ACU

3.1.2 Alarm Displays

3.1.2.1 General Alarms

Alarm
Flash Version Mismatch
Flash Data Corrupt
NVRAM Version Mismatch
NVRAM Data Corrupt
Emergency Stop

3.1.2.2 Azimuth

Alarm
Description/Recommended Action
Runaway
Antenna was not attempting to move the axis and the RC4080 sensed movement
outside of the runaway slop configuration item range. Verify axis movement working
as expected and that the runaway slop configuration item is set properly.
Jammed
Antenna was attempting to move the axis and the RC4080 did not sense the amount of
movement defined by the jam slop configuration item. Verify axis movement working
as expected and that the jam slop configuration item is set properly.

3.1.2.3 Elevation

Alarm
Description/Recommended Action
Runaway
Antenna was not attempting to move the axis and the RC4080 sensed movement
outside of the runaway slop configuration item range. Verify axis movement working
as expected and that the runaway slop configuration item is set properly.
Jammed
Antenna was attempting to move the axis and the RC4080 did not sense the amount of
movement defined by the jam slop configuration item. Verify axis movement working
as expected and that the jam slop configuration item is set properly.

3.1.2.4 Polarization

Alarm
Description/Recommended Action
Runaway
Antenna was not attempting to move the axis and the RC4080 sensed movement
outside of the runaway slop configuration item range. Verify axis movement working
as expected and that the runaway slop configuration item is set properly.
Jammed
Antenna was attempting to move the axis and the RC4080 did not sense the amount of
movement defined by the jam slop configuration item. Verify axis movement working
as expected and that the jam slop configuration item is set properly.
Chapter 5
Description/Recommended Action
Flash Memory Structure error. Reset defaults, recalibration of controller
will be required.
Items in Flash Memory are corrupt. Reset defaults, recalibration of
controller will be required.
NVRAM version doesn't match Flash Memory version. Reset Defaults,
recalibration of controller will be required.
Items in NVRAM are corrupt. Reset defaults, recalibration of controller
will be required.
The emergency stop input on the controller is currently open. Reset the
input to clear alarm.