TROUBLE
1. Mixer will not
1.1 Electrical service down.
operate
1.2 Burned switch contacts.
1.3 Timer not turned on.
1.4 Motor capacitor defective (1PH only)
1.5 Burned out motor.
1.6 Magnetic starter tripped due to
1.7 Safety Ring not mounted and closed.
1.8 Bowl not raised.
2. Mixer runs but
2.1 Shifting speed with the mixer not
agitator will
not turn.
2.2 Broken or slipping belt.
2.3 Key or pin sheared on input shaft,
3. Agitator stalls
3.1 Loose belt.
during mixing
3.2 Mixer bowl is over-loaded.
3.3 Speed set too high for the mix.
3.4 Contamination of belt with grease.
4. Speeds will
4.1 Loose belt.
not change
properly.
4.2 Vari-speed pulley inoperable.
5. Mixer runs but
5.1 Mixer bowl is over-loaded.
repeatedly cuts
out and stops
5.2 Speed set too high for the mix.
5.3 Service voltage too low or fluctuating.
5.4 Starter improperly set.
6. Attachments
6.1 Dented bowl.
contact bottom
6.2 Bowl height is set too high.
of bowl.
7. Attachments
7.1 Dented bowl.
contact side of
7.2 Insufficient clearance between bottom
bowl.
8. Excessive
6.1 Gears need to be repacked with grease
noise.
6.2 Badly worn or frayed drive belts.
6.3 Attachments hitting bowl.
6.4 Overloaded mixing bowl.
* Remedies designated with an * require the service of an authorized service agent.
TROUBLE-SHOOTING GUIDE
POSSIBLE CAUSE
overload.
running.
input gear, bevel pinion, vertical shaft
or beater shaft
of bowl and beater.
or oil level is low.
1.1 Check electrical service. Replace fuse or
reset circuit breaker as necessary.
1.2 Replace or clean contacts. *
1.3 Turn timer on.
1.4 Replace capacitor. *
1.5 Remove, test, repair or replace. *
1.6 Wait several minutes and push start button.
1.7 Install Safety Ring.
1.8 Raise bowl completely.
2.1 With mixer running, slowly move speed
control lever forward then backward to re-
engage belt.
2.2 Tighten or replace. *
2.3 Notify a service agent.
3.1 Readjust pulley center distance to tighten
belt. *
3.2 Adjust contents of bowl per Mixing
Capacities Table.
3.3 Shift speed lower till beater head rotates
smoothly.
3.4 Clean pulleys and replace belt. *
4.1 Readjust pulley center distance to tighten
belt. *
4.2 Remove, clean and lubricate or
replace.*
5.1 Adjust contents of bowl per Mixing
Capacities Table.
5.2 Shift speed lower till beater head rotates
smoothly.
5.3 Check electrical voltage.*
5.4 Adjust amp setting on starter.*
6.1 Remove dent or replace bowl.
6.2 Reset bowl height. *
7.1 Remove dent or replace bowl.
7.2 Adjust bowl height. *
6.1 Notify a service agent.
6.2 Replace belt. *
6.3 Inspect for cause in items 5 above.
6.4 Adjust contents of bowl per Mixing
Capacities Table.