Troubleshooting Guide - Univex Max series 8512 Instruction Manual

Hide thumbs Also See for Max series 8512:
Table of Contents

Advertisement

TROUBLE
1. Slicer will not operate.
1.1 Electrical service down.
1.2 Burned switch contacts.
1.3 Motor capacitor defective.
1.4 Burned out motor.
2. Motor running, blade
2.1 Broken gear
not turning, (carriage)
still operating).
3. Carriage not operating
3.1 Loose or broken belt
(blade is operating).
3.2 Cone clutch assembly not
3.3 Connecting rod support
4. Excessive noise.
4.1 Blade contacting knife
4.2 Deflector contacting blade.
4.3 Sharpener contacting blade
4.4 Connecting rod support
4.5 Fan hitting motor cover.
4.6 Damaged belt hitting
4.7 Reduction gearbox.
5. Not cutting properly.
5.1 Dull blade.
5.2 Soft cheese.

TROUBLESHOOTING GUIDE

POSSIBLE CAUSE
engaging.
jammed.
guard.
hitting bottom cover.
against motor cover.
Page 8
REMEDY
1.1 Check electrical service.
Replace fuse or reset circuit
breaker as necessary.
1.2 Clean or replace. 1.3 Replace
1.4 Remove, test, repair or replace.
2.1 Replace gear
3.1 Adjust belt tension or
replace belt.
3.2 Adjust spring bushing.
3.3 Check for foreign objects in
mechanism.
4.1 Check for loose knife guard
knob. Shim tapered bushing.
4.2 Adjust deflector.
4.3 Adjust cover from hitting
blade.
4.4 Pull bottom cover from
support.
4.5 Remove cover and adjust fan.
4.6 Replace belt.
4.7 Replace.
5.1 Sharpen blade following
outlined procedures.
5.2 Chill for best slicing results.