Important Notice - Emerson Rosemount 8732 Quick Installation Manual

Magnetic flowmeter system
Table of Contents

Advertisement

Rosemount 8732
© 2014 Rosemount Inc. All rights reserved. All marks property of owner.
Emerson Process Management
Rosemount Flow
7070 Winchester Circle,
Boulder, CO 80301
Tel (USA) 800 522 6277
Tel (International) +1 (303) 527 5200
Fax +1 (303) 530 8459
This document provides basic installation guidelines for the Rosemount
provide instructions for detailed configuration, diagnostics, maintenance, service,
troubleshooting, explosion-proof, flame-proof, or intrinsically safe (I.S.) installations. Refer to
the Rosemount 8732 reference manual (document number 00809-0100-4662) for more
instructions. The manual and this QIG are also available electronically on
www.rosemount.com.
Failure to follow these installation guidelines could result in death or serious injury:
Installation and servicing instructions are for use by qualified personnel only. Do not perform
any servicing other than that contained in the operating instructions, unless qualified. Verify
that the operating environment of the sensor and transmitter is consistent with the
appropriate FM, CSA, ATEX, or IECEx approval.
Do not connect a Rosemount 8732 to a non-Rosemount sensor that is located in an explosive
atmosphere.
The sensor liner is vulnerable to handling damage. Never place anything through the sensor
for the purpose of lifting or gaining leverage. Liner damage can render the sensor useless.
To avoid possible damage to the sensor liner ends, do not use metallic or spiral-wound
gaskets. If frequent removal is anticipated, take precautions to protect the liner ends. Short
spool pieces attached to the sensor ends are often used for protection.
Correct flange bolt tightening is crucial for proper sensor operation and life. All bolts must be
tightened in the proper sequence to the specified torque limits. Failure to observe these
instructions could result in severe damage to the sensor lining and possible sensor
replacement.
Rosemount 8705 Magnetic Flowtube units ordered with non-standard paint options may be
subject to electrostatic discharge.
To avoid electrostatic charge build-up, do not rub the meter body with a dry cloth or clean
with solvents.
2
Emerson Process
Management Flow
Neonstraat 1
6718 WX Ede
The Netherlands
T +31 (0)318 495555
F +31(0) 318 495556

IMPORTANT NOTICE

WARNING
WARNING
WARNING
Quick Installation Guide
00825-0100-4662, Rev CD
Emerson FZE
P.O. Box 17033
Jebel Ali Free Zone
Dubai UAE
Tel +971 4 811 8100
Fax +971 4 886 5465
June 2013
Emerson Process
Management Asia Pacific
Private Limited
1 Pandan Crescent
Singapore 128461
T (65) 6777 8211
F (65) 6777 0947/65 6777 0743
®
8732. It does not

Advertisement

Table of Contents
loading

Table of Contents