Error Codes - Elation PROTEUS BEAM WMG PRB162 User Manual

Table of Contents

Advertisement

Error Codes are subject to change without any prior written notice.
ERROR CODE
PAN Er
TILT Er
Cyan
Wheel Er
Magenta
Wheel Er
Yellow
Wheel Er
Color
Wheel Er
Rotating Gobo
Wheel Er
E R R O R C O D E S
DESCRIPTION
The PAN movement is not located in the default position after the reset.
This message will appear after a fixture reset if the magnetic-indexing circuit
malfunctions (sensor failed or magnet is missing) or there is a motor failure
(defective motor or a defective motor IC drive on the main PCB). This error may
also be displayed if the head/yoke was blocked during a reset function.
The TILT movement is not located in the default position after the reset.
This message will appear after a fixture reset if the magnetic-indexing circuit
malfunctions (sensor failed or magnet is missing) or there is a motor failure
(defective motor or defective motor IC drive on main PCB). This error may also be
displayed if the head was blocked during a reset function.
The Cyan Color Wheel is not located in the default position after the reset.
This message will appear after the reset of the fixture reset if the magnetic-
indexing circuit malfunctions (sensor failed or magnet is missing) or there is a
stepper motor failure (defective motor or defective motor IC drive on main PCB).
The Magenta Color Wheel is not located in the default position after the reset. This
message will appear after the reset of the fixture reset if the magnetic-indexing
circuit malfunctions (sensor failed or magnet is missing) or there is a stepper
motor failure (defective motor or defective motor IC drive on main PCB).
The Yellow Color Wheel is not located in the default position after the reset.
This message will appear after the reset of the fixture reset if the magnetic-
indexing circuit malfunctions (sensor failed or magnet is missing) or there is a
stepper motor failure (defective motor or defective motor IC drive on main PCB).
The Color Wheel is not located in the default position after the reset.
This message will appear after the reset of the fixture reset if the magnetic-
indexing circuit malfunctions (sensor failed or magnet is missing) or there is a
stepper motor failure (defective motor or defective motor IC drive on main PCB).
The Rotating Gobo Wheel movement is not located in the default position after the
reset. This message will appear after a fixture reset if the gobo wheel's magnetic-
indexing circuit malfunctions (sensor failed or magnet is missing) or there is a
stepper motor failure (defective motor or defective motor IC drive on main PCB).
53

Advertisement

Table of Contents
loading

This manual is also suitable for:

Proteus beam prb01412370001821237000163