ERROR CODE
Rotating Gobo
Rotation Er
Fixed Gobo
Wheel Er
Prism Er
Focus Er
Frost
Wheel Er
E R R O R C O D E S
DESCRIPTION
The Rotating Gobo rotation movement is not located in the default position after
the reset. This message will appear after a fixture reset if the gobo wheel's
magnetic-indexing circuit malfunctions (sensor failed or magnet is missing) or
there is a stepper motor failure (defective motor or defective motor IC drive on
main PCB).
The Fixed Gobo Wheel movement is not located in the default position after the
reset. This message will appear after a fixture reset if the gobo wheel's magnetic-
indexing circuit malfunctions (sensor failed or magnet is missing) or there is a
stepper motor failure (defective motor or defective motor IC drive on main PCB).
The Prism Wheel 1movement is not located in the default position after the reset.
This message will appear after a fixture reset if the gobo wheel's magnetic-
indexing circuit malfunctions (sensor failed or magnet is missing) or there is a
stepper motor failure (defective motor or defective motor IC drive on main PCB).
The Focus movement is not located in the default position after the reset.
This message will appear after the reset of the fixture reset if the magnetic-
indexing circuit malfunctions (sensor failed or magnet is missing) or there is a
stepper motor failure (defective motor or defective motor IC drive on main PCB).
The Frost Wheel is not located in the default position after the reset.
This message will appear after the reset of the fixture reset if the magnetic-
indexing circuit malfunctions (sensor failed or magnet is missing) or there is a
stepper motor failure (defective motor or defective motor IC drive on main PCB).