Rtlc-S Installation Drawing - Renishaw T103x Installation Manual

Rtlc-s linear encoder system
Table of Contents

Advertisement

RTLC-S installation drawing

START
NOTE: The reference mark selector
and limit actuator locations are correct
for the readhead orientation shown.
Ra 3.2
Detail A
±1
15
11.7
16.2
TONiC RTLC-S installation guide
(adhesive datum clamp)
Measuring length ML = ( L-17) (ML = ( L-32) with dual limits)
5
0.5
F
0.2/100
F = axis of motion
P limit magnet
Readhead optical detector position at extent of travel
Nominal P limit
trigger point (±3)
Detail B
3.7
12
Overall length ( L + 37 )
Scale length ( L )
Optical centreline (incremental and reference mark)
Detail C
End cover
alignment
indicator
3.5
A
Reference mark
selector magnet
Q limit magnet
Datum clamp
(A-9585-0028)
Nominal Q limit
F
0.05
trigger point (±3)
F = axis of motion
Optional bolted reference mark selector (A-9653-0290) or
limit magnets (Q limit A-9653-0291, P limit A-9653-0292)
2.0
B
0.8
Ø2.2*
3.7
B
*Supplied with 2 x M2 x 4 Triffix screws.
Dimensions and tolerances in mm
FINISH
5
8
B
Optional end cover
(Pair A-9585-0035)
C
22
18
10
1.85
18.5 ±1
4

Advertisement