Torque Settings For Screws - Elation PROTEUS LUCIUS PRL546 User Manual

Table of Contents

Advertisement

T O R Q U E S E T T I N G S F O R S C R E W S
The hex-head screws holding either the panels or the base MUST be tightened with a
torque wrench (not included).
TORQUE SETTING
11 lbf-in. (12.7kgf-cm)*
* lbf-in = Pound Force Inches
kgf-cm = Kilogram Force Centimeters
CAUTION! DO NOT OVER TORQUE SCREWS AS
THIS CAN CAUSE LEAKAGE ISSUES!
TO CONFIRM THE IP65 INTEGRITY AFTER A
LAMP REPLACEMENT, TEST FIXTURE USING
THE ELATION IP TESTER. CONTACT ELATION
SERVICE FOR MORE DETAILS.
CAUTION! THE USE OF PROTECTIVE GLOVES
AND
SAFETY
GOGGLES
RECOMMENDED WHILE PERFORMING THE IP
PRESSURE TEST! AVOID PLACING YOUR FACE,
EYES, HANDS, ETC IN CLOSE PROXIMITY TO
THE FIXTURE'S LENS WHILE PERFORMING
THE TEST!
IP PRESSURE
TESTING
PARAMETERS
Test Type
Vacuum Test
Pressure Test
IS
STRONGLY
Low Pressure Limit High Pressure Limit Hold Time
-4.35psi
(-30.00 KPa)
3.62 psi
(25.00 KPa)
16
-5.08 psi
(-35.00 KPa)
4.35 psi
(30.00 KPa)
10s
10s