Waterfall 250™
To run a unit or units in stand alone mode with a built in waterfall
program, follow the dipswitch chart below. This for either setting a
certain color or a certain waterfall effect.
Elation Professional
- www.elationlighting.com - Waterfall 250™Instruction Manual Page 11
©
®
Dipswitch Settings
Waterfall 250™
Caution:
Always replace with the exact same type lamp, unless
otherwise specified by an authorized
Replacing with anything other than the specified part can damage
your unit and will void your manufactures warranty.
Warning:
If you continue to blow lamps or the fuse, STOP using the
unit. Contact customer support for further instructions, you may have
to return the unit for servicing. Continuing to use the unit may cause
serious damage.
Fuse Replacement: Locate and remove the unit's power cord. Once
the cord has been removed located the fuse holder located inside the
power socket. Insert a flat-head screw driver into the power socket and
gently pry out the fuse holder. Remove the bad fuse and replace with a
new one. The fuse holder has a built-in socket for a spare fuse be sure
not to confuse the spare fuse with the active fuse.
Lamp Replacement:
Caution! Never attempt to change the lamp
while the fixture is plugged in. Always disconnect the main power and
allow the unit ample time to cool before attempting to replace the
lamp. Lamp replacement has been made simple by incorporating the
use of a trap door that is retained by thumb screws.
1. Be sure to follow the proper handling procedures that deal with
discharge lamps.
2. Remove the thumb screw on the trap door located at the rear of
the unit.
3. Slide out the lamp socket assembly to expose the lamp.
4. Carefully remove the old lamp. NEVER TOUCH A DISCHARGE
LAMP WITH YOUR BARE HANDS. NEVER DISCARD A
DISCHARGE LAMP IN THE TRASH. FOR PROPER DISPOSAL
INSTRUCTIONS, PLEASE REFER TO THE INSTRUCTIONS
INCLUDED WITH YOUR NEW DISCHARGE LAMP.
5. Replace the lamp with an exact match and reassemble in reverse
order.