S YS T E M M E N U
MAIN MENU
OPTIONS / VALUES (Default Settings in BOLD)
Set Dmx Address A001~AXXX
Dmx Value
Function
Secondary Mode
Auto Program
Time Information
Temperature Info
Humidity Info
Information
Ethernet IP
Fan Info
Software Version Vx.x.x
Error Info
Status Settings
Personality
Service Setting
Fans Control
Display Setting
PAN......
Secondary1, Secondary2, Secondary3
Primary / Alone
Current Time
XXXX(Hours)
Total Run Time
XXXX(Hours)
Last Run Time
XXXX(Hours)
LastRun Password Password=XXX
Clear Last Run
ON/OFF
LED Temperature XXX℃/℉
Base Temperature XXX℃/℉
Head Temperature XXX℃/℉
Base Humidity
XXX%
Head Humidity
XXX%
Ethernet IP
XXX. XXX. XXX. XXX
XXX. XXX. XXX. XXX
HeadFan1: xxxx RPM
............
Error Record 1
Error Record 2
... ...
Error Record 10
Address Via DMX ON/OFF
No DMX Status
Close/Hold/Auto/SunProt Auto Run If No DMX
Pan Reverse
ON/OFF
Tilt Reverse
ON/OFF
Pan Degree
630/540
Feedback
ON/OFF
Movement Speed Normal/Slow
CMY Speed
Normal/Fast
P/T Brake Mode
Smooth/Fast
Gobo Color Cor.
Enable/Disable
Hibernation
OFF, 01M~99M,15M
Password
Password=XXX
Clear Err. Info
ON/OFF
Auto/ High/ Low/ Studio/ Mute
Shutoff Time
02~60m 05m
Display Reverse
OFF/ON/AUTO
Key Lock
ON/OFF
27
DESCRIPTION
DMX Address Setting
DMX Value Display
Secondary Setting
Auto Program
Power On Running Time
Fixture Running Time
Fixture Last Times Clear
Timer Password 038
Clear Fixture Last Time
Temperature in LED
Temperature in Base
Temperature in Fixture
Humidity in Base
Humidity in Fixture
Ethernet IP
Fan information
Software Version
Address Via DMX
Pan Reverse movement
Tilt Reverse movement
Pan Degree Select
Movement Feedback
Movement Speed
Adjust CMY speed
P/T Brake Mode
Cobo Color Correction
Standby Mode
Password"=050"
Clear Err. Info
Fans Control
Display Shut Off Time
Reverse 180 degree
LCD Control Panel Key Lock