6 - LIST OF PARAMETERS
No. Description
2
100 Language
2
101 Date
2
102 Hour
1
103 Control type
2
104 Leak detection
2 104,1 Leak detection time delay
2
108 Pump 2 control
2
109 Pump 2 'on' time delay
2
111 Configurable output
2
112 Number of electric stages
2
113 Configurable input
3
115 Exchanger frost detection enabled
3
116 Drycooler link
2
117 Power input limitation
2 118,1 Maximum power level
Setpoint Management
1
119 Operating mode
1
120 Number of setpoints
1
121 Cooling setpoint 1
1
122 Cooling setpoint 2
1
123 Heating setpoint 1
1
124 Heating setpoint 2
1 125,1 Low setpoint (4 20 mA) during cooling:
1 125,2 Low setpoint (4 20 mA) during heating:
1 126,1 High setpoint (4 20 mA) in cooling mode:
1 126,2 High setpoint (4 20 mA) in heating mode:
1
127 Cooling setpoint adjustment = f (out. temp.) No - Yes
1
128 Outdoor temperature at start of drift
1
129 Outdoor temperature at end of drift
1
130 Maximum setpoint at end of drift
Heating setpoint adjustment = f (out.
1
131
temp.)
1
132 Outdoor temperature at start of drift
1
133 Outdoor temperature at end of drift
1
134 Maximum setpoint at end of drift
1
135 Minimum boiler drift setpoint
136 Maximum air temperature in automatic
1
heating mode
137 Minimum air temperature in automatic
1
cooling mode
18
Setting
Configuration Client
F - GB - D - SP - I
DAy/MOnth/YEar
HOurs/MInutes
Local - remote (BMS)
Yes - No
0 to 5 min
Depending on control mode
Depending on On/Off if P2 = 1
15 to 90 seconds (resolution: 5
seconds)
Max. power/Boiler/Cooling-heating
/ Helping on all faults on air-to-
water only
1 to 4
Disabled/Load shedding/Override
Yes - No
Yes - No
No permanent – Yes by on/off input
– Yes by bus
15 to 400 kW
1 - Cooling
2 - Heating
3 - Cooling/heating via console
4 - Cooling/heating via on/off input
5 - Automatic cooling/heating
based on outdoor temperature
1 - 2 via console - 2 via on/off input
- 3 Setpoint managed by 4 20 mA
signal
P52 + 1 K at 30°C (resolution: 0,1)
P52 + 1 K at 30°C (resolution: 0,1)
20 to 60°C (resolution: 0,1)
20 to 60°C (resolution: 0,1)
P52 + 3 K at 30°C 
10 to 60°C
P125,1 ± 5 K at 30°C with 
minimum value of P52 + 3
P125,2 ± 5 K at 60°C with 
minimum value of 10°C.
 20 to 55°C (resolution: 1)
P128 + 5 K at 60°C (resolution: 1)
P52 + 1 K at 30°C (resolution: 0,1)
No - Yes
 20 to 55°C (resolution: 1)
-25 to P132 - 5 K (resolution: 1)
Highest setpoint if P120 ≠ 1 or 
setpoint if P120 = 1 at 60°C 
(resolution: 0,1)
30 to 55°C
- 5 to 25°C (resolution 1)
P136 + 2 to 40°C (resolution: 1)
Default
Display conditions
F
Local
NO
1 min
If P104 = Yes
Depending on
Visible if P2 = 1
On/Off
Visible if P2 = 1
15
and P108 = f (Control)
P max
2
Visible if P22 = Yes
Disabled
Visible if P22 = Yes
Yes
Visible if P2 = 1, 2, 3
No
No
P 15,1 = Yes
200
P 15,1 = Yes and P117 ≠ No
If P2 = 1 or 3 = All
Cooling
If P2 = 2 = Cooling only
1
20
If P2 = 1, 2 or 3 P119 ≠ Heating
15
If P120 = 2, P2 = 1, 2 or 3,
25
P119 ≠ Heating
20
P119 ≠ Cooling
Displayed if P120 = 3 and in cooling
P52 + 3
mode
Displayed if P120 = 3 and in heating
20
mode
Displayed if P120 = 3 and in cooling
20
mode
Displayed if P120 = 3 and in heating
40
mode
Yes
If P2 = 1, 2 or 3 and P119 ≠ Heating
25
If P127 = Yes
35
If P127 = Yes
10
If P127 = Yes
Yes
If P2 = 1 or 3 and P119 ≠ Cooling
16
If P131 = Yes
-7
If P131 = Yes
45
If P131 = Yes
50°C
If P111 = Boiler
16
If P119 = 5
20
If P119 = 5