Installation With Solvent Cement Sockets; Installation With Flare Connection - GEM R639 eSyStep Operating Instructions Manual

Motorized diaphragm valve
Hide thumbs Also See for R639 eSyStep:
Table of Contents

Advertisement

10 Installation in piping

10.6 Installation with solvent cement sockets

NOTICE
▶ The solvent cement is not included in the scope of deliv-
ery.
Only use suitable solvent cement!
1. Carry out preparations for installation (see chapter "Pre-
parations for installation").
2. Apply solvent cement on the inside of the valve body and
on the outside of the piping as specified by the solvent ce-
ment manufacturer.
3. Connect the body of the product with the piping.
4. Reactivate all safety and protective devices.

10.7 Installation with flare connection

NOTICE
Fittings!
▶ For preparation and connection of the flare connections,
please refer to the GEMÜ FlareStar
GEMÜ flare and assembly instructions.
Depending on the ambient conditions, use resistant and
suitable connection fittings.
1. Carry out preparations for installation (see chapter "Pre-
parations for installation").
2. Push the flared PFA tubing onto the flare fitting body.
3. Screw the union nut over it.
4. Re-attach or reactivate all safety and protective devices.
GEMÜ R639 eSyStep
OPEN / CLOSE (Code AE)
®
brochure and the
34 / 71
www.gemu-group.com

Advertisement

Table of Contents
loading