10 Installation in piping
10.6 Installation with solvent cement sockets
NOTICE
▶ The solvent cement is not included in the scope of deliv-
ery.
Only use suitable solvent cement!
●
1. Carry out preparations for installation (see chapter "Pre-
parations for installation").
2. Apply solvent cement on the inside of the valve body and
on the outside of the piping as specified by the solvent ce-
ment manufacturer.
3. Connect the body of the product with the piping.
4. Reactivate all safety and protective devices.
10.7 Installation with flare connection
NOTICE
Fittings!
▶ For preparation and connection of the flare connections,
please refer to the GEMÜ FlareStar
GEMÜ flare and assembly instructions.
Depending on the ambient conditions, use resistant and
●
suitable connection fittings.
1. Carry out preparations for installation (see chapter "Pre-
parations for installation").
2. Push the flared PFA tubing onto the flare fitting body.
3. Screw the union nut over it.
4. Re-attach or reactivate all safety and protective devices.
GEMÜ R639 eSyStep
OPEN / CLOSE (Code AE)
®
brochure and the
34 / 71
www.gemu-group.com