Mounting The Actuator - GEM R639 eSyStep Operating Instructions Manual

Motorized diaphragm valve
Hide thumbs Also See for R639 eSyStep:
Table of Contents

Advertisement

ð The diaphragm boss must fit closely in the recess of
the compressor.
8. If it is difficult to screw it in, check the thread and replace
damaged parts.
9. When definitive resistance is felt, turn back the diaphragm
until its bolt holes are in correct alignment with the bolt
holes of the actuator.
10. Press the diaphragm face tightly onto the backing dia-
phragm manually so that it returns to its original shape
and fits closely on the backing diaphragm.
11. Align the weir of compressor and diaphragm in parallel.
13.5.2 Mounting the concave diaphragm
Recess of compressor
Diaphragm boss
1. Move the actuator A to the closed position.
2. Mount the compressor (see "Mounting the compressor").
3. Check if the compressor is fitted in the guides.
4. Manually screw new diaphragm tightly into the com-
pressor.
5. Check if the diaphragm boss fits closely in the recess of
the compressor.
6. If it is difficult to screw it in, check the thread and replace
damaged parts.
7. When definitive resistance is felt, turn back the diaphragm
until its bolt holes are in correct alignment with the bolt
holes of the actuator.
8. Align the weir of compressor and diaphragm in parallel.

13.6 Mounting the actuator

NOTICE
Diaphragms set in the course of time.
▶ Leakage
After disassembly/assembly of the product, check that
the bolts and nuts on the body are tight and retighten if
required.
Retighten the bolts and nuts at the very latest after the
first sterilization process.
1. Move the actuator A to the open position.
2. Position actuator A with the mounted diaphragm on the
valve body 1.
3. Screw in bolts, washers and nuts hand tight.
www.gemu-group.com
ð Fastening elements may vary depending on the dia-
phragm size and/or valve body version.
4. Move the actuator A to the closed position.
5. Open actuator A approx. 20%.
6. Fully tighten the bolts with nuts diagonally.
7. Ensure even compression of the diaphragm (approx. 10 to
15%).
ð Even compression is detected by an even bulge to the
outside.
Please note: For a code 5M diaphragm (convex dia-
phragm), the PTFE diaphragm face and the EPDM
Diaphragm pin
backing diaphragm must be positioned level with and
parallel to the valve body.
8. With the valve fully assembled, check the function and
tightness.
9. Carry out initialisation.