User Action:
Information only; no action is required
• FQXSPPW0031J: Numeric sensor [NumericSensorElementName] going low (lower non-critical) has
asserted.
This message is for the use case when an implementation has detected a Lower Non-critical sensor going
low has asserted.
Severity: Warning
Serviceable: Yes
Automatically notify Support: No
Alert Category: Warning - Voltage
SNMP Trap ID: 13
CIM Prefix: PLAT CIM ID: 0476
User Action:
CMOS battery is recommended to replace with new one. If the problem persist, replace the system board.
• FQXSPPW0035M: Numeric sensor [NumericSensorElementName] going low (lower critical) has
asserted.
This message is for the use case when an implementation has detected a Lower Critical sensor going low
has asserted.
Severity: Error
Serviceable: Yes
Automatically notify Support: Yes
Alert Category: Critical - Voltage
SNMP Trap ID: 1
CIM Prefix: PLAT CIM ID: 0480
User Action:
CMOS battery is recommended to replace with new one. If the problem persist, replace the system board.
• FQXSPPW0057J: Sensor [SensorElementName] has transitioned from normal to non-critical state.
This message is for the use case when an implementation has detected a Sensor transitioned to non-
critical from normal.
Severity: Warning
Serviceable: Yes
Automatically notify Support: No
Alert Category: Warning - Power
SNMP Trap ID: 164
CIM Prefix: PLAT CIM ID: 0520
User Action:
Please check event log in xClarity Controller web interface.
• FQXSPPW0061M: Sensor [SensorElementName] has transitioned to critical from a less severe
state.
This message is for the use case when an implementation has detected a Sensor transitioned to critical
from less severe.
Severity: Error
Serviceable: Yes
94
ThinkSystem SE360 V2 Messages and Codes Reference