User Action:
Check the event log in system event log to resolve any issues related the NMI
• FQXSPIO0007N: A PCI PERR has occurred on system [ComputerSystemElementName].
This message is for the use case when an implementation has detected a PCI PERR.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Other
SNMP Trap ID: 50
CIM Prefix: PLAT CIM ID: 0232
User Action:
Complete the following steps to solve the problem:
1. Reseat the adapter or install in to another slot.
2. If the problem still exists, then replace the adapter.
3. If the problem still exists, then contact local service.
• FQXSPIO0008N: A PCI SERR has occurred on system [ComputerSystemElementName].
This message is for the use case when an implementation has detected a PCI SERR.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Other
SNMP Trap ID: 50
CIM Prefix: PLAT CIM ID: 0234
User Action:
Complete the following steps to solve the problem:
1. Reseat the adapter or install in to another slot.
2. If the problem still exists, then replace the adapter.
3. If the problem still exists, then contact local service.
• FQXSPIO0010I: A Correctable Bus Error has occurred on bus [SensorElementName].
This message is for the use case when an implementation has detected a Bus Correctable Error.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID:
CIM Prefix: PLAT CIM ID: 0238
User Action:
Information only; please correct the error recorded in system log to resolve the error
• FQXSPIO0011N: An Uncorrectable Error has occurred on [SensorElementName].
This message is for the use case when an implementation has detected a Bus Uncorrectable Error.
Severity: Error
50
ThinkSystem SE360 V2 Messages and Codes Reference