Lenovo ThinkSystem SE360 V2 Manual page 144

Table of Contents

Advertisement

Table 3. Events organized by severity (continued)
Message String
Event ID
FQXSFIO0009M
An inter-board UPI dynamic link width reduction has been detected
on the link between processor [arg1] port [arg2] and processor [arg3]
port [arg4].
FQXSFIO0013I
The device found at Bus [arg1] Device [arg2] Function [arg3] could not
be configured due to resource constraints. The Vendor ID for the
device is [arg4] and the Device ID is [arg5]. The physical slot number
is [arg6].
FQXSFIO0016M
IFM: Reset loop avoided - Multiple resets not allowed.
FQXSFIO0021J
PCIe Error Recovery has occurred in physical [arg1] number [arg2].
The [arg3] may not operate correctly.
FQXSFIO0022J
PCIe Link Width has degraded from [arg1] to [arg2] in physical [arg3]
number [arg4].
FQXSFIO0023J
PCIe Link Speed has degraded from [arg1] to [arg2] in physical [arg3]
number [arg4].
FQXSFIO0024I
An error has been detected by the IEH on processor [arg1]. The type
of IEH is [arg2]. The index of the IEH is [arg3]. The value of
IehErrorStatus register is [arg4]. Please check error logs for additional
downstream device error data.
FQXSFIO0025I
An error has been detected by the IIO on processor [arg1]. The index
of the IIO stack is [arg2]. The type of IIO Internal Error is [arg3]. Please
check error logs for additional downstream device error data.
FQXSFIO0032M
PCIe Correctable Error PFA Threshold limit has been exceeded at Bus
[arg1] Device [arg2] Function [arg3]. The Vendor ID for the device is
[arg4] and the Device ID is [arg5]. The physical bay number is [arg6].
FQXSFIO0033J
PCIe Link Width has degraded from [arg1] to [arg2] in physical bay
number [arg3].
FQXSFIO0034J
PCIe Link Speed has degraded from [arg1] to [arg2] in physical bay
number [arg3].
FQXSFMA0012L
The [arg1] PFA Threshold limit has been exceeded on DIMM [arg2] at
address [arg3]. [arg4]
FQXSFMA0016M
Memory spare copy failed. [arg1]
FQXSFMA0026G
Multi-bit CE occurred on DIMM [arg1], need to restart the system for
DIMM Self-healing to attempt post package repair (PPR)
FQXSFMA0027M
DIMM [arg1] Self-healing, attempt post package repair (PPR) failed at
Rank [arg2] Sub Rank [arg3] Bank [arg4] Row [arg5] on Device [arg6].
[arg7]
FQXSFMA0028M
DIMM [arg1] Self-healing, attempt post package repair (PPR)
exceeded DIMM level threshold [arg2] at Rank [arg3] Sub Rank [arg4]
Bank [arg5] Row [arg6] on Device [arg7]. [arg8]
FQXSFMA0030K
Intel Optane PMEM [arg1] Percentage Remaining is less than [arg2]%
and still functioning.
FQXSFMA0031K
Intel Optane PMEM [arg1] has reached 1% remaining spares block
and still functioning.
FQXSFMA0033M
Intel Optane PMEM persistent memory interleave set has [arg1]
PMEMs(DIMM [arg2]), [arg3] DIMMs' location is not correct.
140
ThinkSystem SE360 V2 Messages and Codes Reference
Severity
Warning
Warning
Warning
Warning
Warning
Warning
Warning
Warning
Warning
Warning
Warning
Warning
Warning
Warning
Warning
Warning
Warning
Warning
Warning

Advertisement

Table of Contents
loading

This manual is also suitable for:

7damThinksystem se360

Table of Contents