• FQXSPPU2002I: The Processor [ProcessorElementName] is no longer operating in a Degraded
State.
This message is for the use case when an implementation has detected a Processor is no longer running
in the Degraded state.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: Warning - CPU
SNMP Trap ID: 42
CIM Prefix: PLAT CIM ID: 0039
User Action:
Information only; no action is required
• FQXSPPW0001I: [PowerSupplyElementName] has been added to container
[PhysicalPackageElementName].
This message is for the use case when an implementation has detected a Power Supply has been added.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID: 22
CIM Prefix: PLAT CIM ID: 0084
User Action:
Information only; no action is required
• FQXSPPW0002L: [PowerSupplyElementName] has Failed.
This message is for the use case when an implementation has detected a Power Supply has failed.
Severity: Error
Serviceable: Yes
Automatically notify Support: Yes
Alert Category: Critical - Power
SNMP Trap ID: 4
CIM Prefix: PLAT CIM ID: 0086
User Action:
Please check event log in xClarity Controller (XCC) Web GUI to identify the power supply unit failure.
Check system spec and replace the power supply unit to the same specification.
• FQXSPPW0003G: Failure predicted on [PowerSupplyElementName].
This message is for the use case when an implementation has detected a Power Supply failure is
predicted.
Severity: Warning
Serviceable: Yes
Automatically notify Support: No
Alert Category: Warning - Power
SNMP Trap ID: 164
CIM Prefix: PLAT CIM ID: 0088