1. Check Lenovo Support site for an applicable service bulletin or firmware update for the system or
adapter that applies to this error.
2. If the problem persists, collect Service Data logs and contact Lenovo Support.
• FQXSFIO0025M: An error has been detected by the IIO on processor [arg1]. The index of the IIO
stack is [arg2]. The type of IIO Internal Error is [arg3]. Please check error logs for additional
downstream device error data.
Severity: Error
User Action:
Complete the following steps:
1. Check Lenovo Support site for an applicable service bulletin or firmware update for the system or
adapter that applies to this error.
2. If the problem persists, collect Service Data logs and contact Lenovo Support.
• FQXSFIO0031M: An Uncorrectable PCIe Error has Occurred at Bus [arg1] Device [arg2] Function
[arg3]. The Vendor ID for the device is [arg4] and the Device ID is [arg5]. The physical bay number is
[arg6].
Severity: Error
User Action:
Complete the following steps:
1. Check Lenovo Support site for an applicable device driver, firmware update, version of service
information for this product or other information that applies to this error. Load new device driver and
any required firmware updates.
2. If this device and/or any attached cables were recently installed, moved, serviced or upgraded.
a. Reseat Adapter and any attached cables.
b. Reload Device Driver.
c. If device is not recognized, reconfiguring slot to Gen1 or Gen2 may be required. Gen1/Gen2
settings can be configured via F1 Setup -> System Settings -> Devices and I/O Ports ->PCIe
Gen1/Gen2/Gen3 Speed Selection, or the OneCLI utility.
d. If a PCIe error has also been reported on a second slot within the same node, ensure steps a, b,
and c above are also performed for that adapter before proceeding.
3. If the problem persists, collect Service Data logs and contact Lenovo Support.
• FQXSFIO0032M: PCIe Correctable Error PFA Threshold limit has been exceeded at Bus [arg1]
Device [arg2] Function [arg3]. The Vendor ID for the device is [arg4] and the Device ID is [arg5]. The
physical bay number is [arg6].
Severity: Warning
User Action:
Complete the following steps:
1. Reboot the system.
2. Reflash the NVME disk firmware.
3. If the problem persists, collect Service Data logs and contact Lenovo Support..
• FQXSFIO0033J: PCIe Link Width has degraded from [arg1] to [arg2] in physical bay number [arg3].
Severity: Warning
User Action:
154