Lenovo ThinkSystem SE360 V2 Manual page 60

Table of Contents

Advertisement

• FQXSPMA0010J: [PhysicalMemoryElementName] on Subsystem [MemoryElementName]
Throttled.
This message is for the use case when an implementation has detected Memory has been Throttled.
Severity: Warning
Serviceable: Yes
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID: 22
CIM Prefix: PLAT CIM ID: 0142
User Action:
if there are dust filter in system, make sure that dust filter is clean.
• FQXSPMA0011G: Memory Logging Limit Reached for [PhysicalMemoryElementName] on
Subsystem [MemoryElementName].
This message is for the use case when an implementation has detected that the Memory Logging Limit
has been Reached.
Severity: Warning
Serviceable: Yes
Automatically notify Support: Yes
Alert Category: Warning - Memory
SNMP Trap ID: 43
CIM Prefix: PLAT CIM ID: 0144
User Action:
Complete the following steps:
1. If the server has recently been installed, moved, serviced, or upgraded, verify that the DIMM is
properly seated and visually verify that there is no foreign material in any DIMM connector on that
memory channel. If either of these conditions is found, correct and retry with the same DIMM. (Note:
The event Log might contain a recent FQXSFMA0011I event denoting detected change in DIMM
population that could be related to this problem.)
2. If no problem is observed on the DIMM connectors or the problem persists, replace the DIMM
identified by LightPath and/or event log entry.
3. If problem recurs on the same DIMM connector, replace the other DIMMs on the same memory
channel.
4. Check Lenovo support site for an applicable service bulletin or firmware update that applies to this
memory error.
5. If problem recurs on the same DIMM connector, inspect connector for damage. If damage found or
problem persists, collect Service Data log.
6. Contact Lenovo Support.
• FQXSPMA0012M: An Over-Temperature Condition has been detected on the
[PhysicalMemoryElementName] on Subsystem [MemoryElementName].
This message is for the use case when an implementation has detected an Over Temperature Condition
for Memory that has been Detected.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Temperature
SNMP Trap ID: 0