6.3

EMC compliant installation

WARNING
High-frequency interference
(radio interference)
If the motor/control electronics are not
installed accordingly the instructions in
operation, it can create Interference with
radio transmission.
Install interference filters.
X
Earth the system additionally.
X
Earth the drive (functional earth „FE")
X
Shield all connecting cables or use shielded connec-
X
ting cables and connect them at both ends to „FE".
Only use CE-compliant power supplies.
X
Lay the interface cables of the power supply separa-
X
tely from the signal lines.
Version 06-02-2023
6.3

EMV-konforme Installation

WARNUNG
Hochfrequente Störungen
(Funkstörungen)
Wird der Motor nicht entsprechend den
Anweisungen in Betrieb genommen und
verwendet, kann es zu Störungen von
Funkübertragung ( oder: Interferenzen)
kommen.
X
X
Erden Sie den Antrieb (Funktionserde"FE")
X
Schirmen Sie alle Verbindungskabel ab oder verwen-
X
den Sie geschirmte Verbindungskabel und legen Sie
diese beidseitig auf „FE".
Verwenden Sie ausschließlich CE-konforme Netzteile.
X
Verlegen Sie die Schnittstellenkabel der Stromversor-
X
gung getrennt von den Signalleitungen.
BG 45
dPro
Installieren Sie Störfilter.
Erden Sie die Anlage zusätzlich.