Replace pump

C01
Prerequisites
• Main PCB cover is removed → p. 74.
Procedure
1. Loosen 1 screw (TX20) on chassis BU (C01).
2. Unplug the 3 wires of the pump (C08) from the main PCB (C17):
(a) Capsule container detection connector
(b) Pump control receptacle
(c) Pump line receptacle
Version 0.1 EN
Repair > Coffee Module repairs > Replace pump
C17
Momento Service manual
Fig. 72 