Repair
Replacing pump
Tools:
Torx screwdriver PinTX10
Longnose pliers
Blade screwdriver, no. 7
Procedure:
1. Follow general disassembly (see page
17).
2. Remove clip (227), hose (205) and Oring
(206).
3. Remove angled hose (204).
4. Release pump (208) first from rubber
strap (213) at the side of the angled hose.
5. Remove electrical connections from
pump.
6. Release pump from second rubber strap
(213).
7. Replace defective pump (208).
8. Attach new pump (208) to one rubber
strap with corner connector (209) first.
9. Plug in electrical connections on pump.
Check for correct wiring of pump.
10. Attach pump to second rubber strap.
11. Insert new Oring (226), mount hose
(205) and clamp (227).
12. Mount angled hose (204).
Service Manual C91 / D91