Repair > Coffee Module repairs > Replace brewing unit (maintenance kit)
Replace brewing unit (maintenance kit)
This procedure should be done at least every 48'000 cycles.
Prerequisites
• Head base plate is removed → p. 76.
Procedure
1. Release the latch of the worm gear support (x) and remove the support (x).
d
C21
2. Slightly pull out the worm gear (y) to be able to freely move the brewing unit
(C21) front assembly (d).
Version 0.1 EN
x
y
Momento Service manual
The brewing unit
does not need
to be detached from
the coffee module for
maintenance.
Fig. 76
Fig. 77
97