Remove Head Base Plate - Nespresso Momento 100 Service Manual

Hide thumbs Also See for Momento 100:
Table of Contents

Advertisement

Danger of
damage! Always
replace the o-ring
when pulling of a hose
adapter from a valve.
76
Repair > Coffee Module repairs > Remove head base plate

Remove head base plate

Prerequisites
• Main PCB cover is removed → p. 74.
Procedure
1. Pull out the connector clip (a) from the hose adapter (C80) with pointed pliers.
2. Pull off the hose (b) with hose adapter (C80) from the valve (C78).
3. Replace the O-ring (C81) seated between valve (C78) and hose adapter (C80).
Momento Service manual
C78
a
C80
b
C81
Version 0.1 EN
Fig. 54 

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Momento 200

Table of Contents