MASONRY INSERT INSTALLATION
This unit (appliance) may be installed into an all masonry fireplace, built in accordance with the
Uniform Building Code and the National Fire Protection Association (NFPA 211).
NOTE: Check with local building officials for any permits required for installation of this unit
and notify your insurance company before proceeding with installation
In some cases, such as improperly drawing fireplaces, oversize flue liners are to meet codes in
certain areas it is recommended that one of the flowing procedures be followed:
A. A Chimney Connector can be installed from the appliance flue exit through the damper
and an air-tight face seal. (See option (A) Page 9).
B. A listed Direct Connect can be installed from the appliance flue exit through the damper
into the first section of the flue liner with air-tight seal. (See option (B) Page 9).
C. A Positive Connect can be installed from the appliance flue exit continuing up through the
entire chimney and exiting at the top of the chimney. (See option (C) Page 9).
NOTE: If mounting trim panels, See Page 8-9.
FINAL CHECK
1. Recheck specified clearances.
2. Remove all foreign material from firebox area.
3. Open the primary air draft.
4. Plug power cord into a 115V AC outlet if optional motor is being used. Do not run cord
under unit or in high traffic areas.
5. Place crumpled pieces of newspaper in the stove. Light it and close door. Ensure that the
stove draws properly through primary draft.
6. Check for smoke leaks around door.
7. Open door and check for smoke escaping from front of stove. Smoking usually indicates
a defective or poorly positioned chimney. Some chimneys with a marginal draft can be
preheated by lighting newspaper and holding it near open damper with a poker or fire tong.
Once the chimney heats up, a proper draft can usually be obtained.
If a thorough review of the Troubleshooting Guide in the manual does not reveal the problem,
contact your dealer for assistance.