HOW TO LOCATE CHIMNEY EXIT AND INSTALL
Residential and Mobile Home Installation
E. Vertical Exit using (6" DVL Close Clearance pipe and any Listed 2100° UL 103 HT
chimney).
With optional close clearance shield and pipe shield. NOTE: For installation of
optional close clearance shields and pipe shield (See Page 35).
NOTE: For minimum clearances see page 26, figure 23.
If pedestal kit is being used and out side air is required (See Pages 15-16).
1. Suspend a plumb bob from ceiling above unit so that weight is hanging in the center of
flue exit. (A small weight on a string will serve as a plumb bob). Mark ceiling where
string is suspended to locate center of chimney. (See Page 26,Figure 24).
2. After locating center of hole, install ceiling support box, chimney or chimney connector,
flashing and rain cap, per chimney manufacturer's instructions and local building codes
for installation through combustible walls or ceilings.
3. Now connect stove and ceiling support box using DVL close clearance pipe.
Connect each section per manufacturer's instructions.
Secure each section to each other using minimum (3) sheet metal screws or rivets.
DVL close clearance is to be connected with (3) sheet metal screws or rivets to
connector collar on heater (See Page 26, Figure 24).
4. NOTE: If your local code requires outside air for residential installation, refer to pages
15-16 for outside air installation.