Section Ii: Masonry Insert Installation - BuckMaster 94NC Preparations, Installation, Operation, Maintenance, Safety

Non-catalytic unit
Hide thumbs Also See for 94NC:
Table of Contents

Advertisement

The Model 94NC may be installed using an all masonry fireplace built in accordance with
Uniform Building Code and National Fire Protection Association (NFPA). The first step in
this type of installation is to determine acceptability of the fireplace and chimney for use with a
woodstove,
both
construction
erations when installing a woodstove. The chimney should extend at least 3' above roof and
at least 2' above any point of roof within 10'.
REMEMBER TO HAVE YOUR CHIMNEY INSPECTED FOR LEAKS AND BLOCKAGE
BEFORE YOU INSTALL YOUR STOVE. DO NOT CONNECT THIS UNIT TO A
CHIMNEY FLUE SERVING ANOTHER APPLIANCE.
MINIMUM CLEARANCE MASONRY INSERT
MODEL 94NC
A. Side Wall Combustible
B. Front Floor Protector
C. Side Floor Protector
D. Side Wood Trim
E. Top Wood Trim
F. Mantel or Brackets
1. The hearth must be of masonry construction and must extend a minimum of 16" in front of
the firebox opening and a minimum of 8" to either side of the firebox opening.
Minimum floor protection under unit must have an R-value of 0.30.
2. If there is no minimum hearth protection from front of firebox opening and front of
masonry hearth, a floor protector must be used in front of hearth to protect combustible
materials. The floor protector must be 3/8" minimum thickness non-combustible material or
equivalent.(See Page 12,13).
SECTION II
MASONRY INSERT INSTALLATION
and
condition
CAUTION
12"
16"
8"
10"
18"
24"
Page 5
of
fireplace
are
important
E
C
C
A
A
consid-
E
F
F
D
D