OPERATING LIMITS
The graphs shown below describe the operating range of the unit.
The maximum permitted temperature of the water for operation
in summer mode is 25 °C.
Above 30°C, the compressor is excluded, leaving only the fan
running.
Between 30 and 60 °C it is possible to activate the ventilation mode
only for use of the appliance in winter.
With water temperatures higher than 60°C, the
appliance could be damaged.
It is important to ensure that the units operate within
the limits shown. Beyond these limits, normal operation is
not guaranteed, nor is the reliability and integrity of the
units (for special applications, contact the manufacturers
technical o ce).
100
95
90
80
70
60
50
40
30
20
10
15 20 25 30 35
Air intake temperature [°C ]
Temperatura ingresso aria [°C ]
100
95
90
80
70
60
50
40
30
20
10
32
23

LIMITI DI FUNZIONAMENTO

I gra ci sottoriportati descrivono il campo operativo dell'unità. La
massima temperatura dell'acqua ammessa nel funzionamento
estivo è di 25 °C.
Al di sopra di 30°C, il compressore viene escluso, lasciando
in funzione solamente il ventilatore. Tra i 30 e 60 °C è
possibile attivare la sola ventilazione per un uso invernale
dell'apparecchio.
Con temperature dell'acqua superiori a 60°C
l'apparecchio potrebbe danneggiarsi.
è importante fare in modo che le unità operino nei
limiti riportati. Al di fuori di tali limiti non sono garantiti
né il normale funzionamento né tantomeno l'a dabilità
e l'integrità delle unità (per applicazioni particolari
contattare l'u cio tecnico del Costruttore).
15
20
25
30
35
40 45 50 55 60 65
Water intake temperature [°C ]