8.1.3.

CiA402 State Chart

CW: Controlword (6040)
SW: Statusword (6041)
(CW: xxxx xxxx 0xxx x110)
(CW: xxxx xxxx 0xxx x110)
(CW: xxxx xxxx 0xxx x111)
(CW: xxxx xxxx 0xxx 1111)
(CW: xxxx xxxx 0xxx xx0x)
Command coding (IEC 61800-7-200/Ed.1.0 Table 27)
Command
Shutdown
Switch on
Switch on + enable operation
Disable voltage
Quick stop
Disable operation
Enable operation
Fault reset
NOTE Automatic transition to Enable operation state after executing SWITCHED ON state
functionality.When detects main power loss or not release main power loss in 3 sec after
change to "Switch on state", the state is changed to "Switch on disable".
START
0
Not Ready to switch on
SW: xxxx xxxx x0xx 0000
1
Switch on disabled
SW: xxxx xxxx x1xx 0000
2
8
Ready to switch on
SW: xxxx xxxx x01x 0001
3
Switch on
SW: xxxx xxxx x01x 0011
4
Operation enable
SW: xxxx xxxx x01x 0111
9
Bits of the controlword
fault
enable
reset
operation
Bit 7
Bit 3
0
x
0
0
0
1
0
x
0
x
0
0
0
1
x
- 44 -
From any state
Fault reaction active
SW: xxxx xxxx x0xx 1111
SW: xxxx xxxx x0xx 1000
7
(CW: xxxx xxxx 0xxx x01x)
( CW: xxxx xxxx 0xxx xx0x)
6
(CW: xxxx xxxx 0xxx x110)
5
(CW: xxxx xxxx 0xxx 0111)
16
11
(CW: xxxx xxxx 0xxx x01x)
Quick
enable
stop
voltage
Bit 2
Bit 1
1
1
1
1
1
1
x
0
0
1
1
1
1
1
x
x
E6581818⑭
13
14
Fault
15
(CW: xxxx xxxx 1xxx xxxx)
10
(CW: xxxx xxxx 0xxx x01x)
(CW: xxxx xxxx 0xxx xx0x)
Quick stop active
SW: xxxx xxxx x00x 0111
switch
Transitions
on
Bit 0
0
2, 6, 8
1
3
1
3 + 4 Note
x
7, 9, 10, 12
x
7, 10, 11
1
5
1
4, 16
x
15
12

Advertisement