then it may be necessary to repeat the checks whilst measuring both the inlet and outlet
pressure to determine if the inlet pressure is in the range 1.13 – 5kPa.
• Check that the regulator has been fitted to the gas supply line in the correct orientation,
the arrow on the base of the body indicates the direction of gas flow.
Once these checks have been completed, if the regulator still fails to perform in a satisfactory
manner it should be replaced.
TABLE 3A – ICGG604W
Burner Type
(Nominal Test point pressure: 1.00kPa)
Auxiliary burner
Semi Rapid burner
Rapid burner
Wok burner
TABLE 3B – ICGG755W, ICGG905W
Burner Type
(Nominal Test point pressure: 1.00kPa)
Auxiliary burner
Semi Rapid burner
Rapid burner
Wok burner
TABLE 3C – ICGG302W
Burner Type
(Nominal Test point pressure: 1.00kPa)
Auxiliary burner
Wok burner
Natural Gas
Injector Size
Gas Consumption
(mm)
(MJ/h)
0.93
1.15
1.72
Natural Gas
Injector Size
Gas Consumption
(mm)
(MJ/h)
0.93
1.15
1.5
1.72
Natural Gas
Injector Size
Gas Consumption
(mm)
(MJ/h)
0.93
1.6
(Nominal Test point pressure: 2.75kPa)
Injector Size
(mm)
4.3
0.58
6.3
0.68
13.5
1.0
(Nominal Test point pressure: 2.75kPa)
Injector Size
(mm)
4.3
0.58
6.3
0.68
10.8
0.9
13.5
1.0
(Nominal Test point pressure: 2.75kPa)
Injector Size
(mm)
4.3
0.58
11.8
0.97
21
LPG
Gas Consumption
(MJ/h)
4.3
6.3
13.5
LPG
Gas Consumption
(MJ/h)
4.3
6.3
10.8
13.5
LPG
Gas Consumption
(MJ/h)
4.3
11.8