Inalto ICGG302W User Manual page 20

30, 60, 75 & 90cm gas on glass cooktops
Table of Contents

Advertisement

Gas Connection (Continued)
ASSEMBLY OF THE REGULATOR
The assembly of the regulator to the cooktop
manifold is achieved via the elbow union and
sealing washer supplied, refer to Figure 7.
The ½" parallel thread connects to the
manifold, and the sealing washer is placed
between the manifold end and the flat face on
the elbow.
The ½" tapered thread connects to the
outlet of the regulator, and is sealed on the
thread using approved thread sealing tape or
approved thread sealing compound.
The inlet of the regulator is a ½" parallel thread
and is connected to consumer piping
or hose assembly.
Regulators are supplied pre-adjusted and
configured by the component maker for use
Gas Connection
with Natural Gas.
Statutory requirements
The appliance installer is not required to make
This installation must conform with the following:
an adjustment to obtain the correct outlet
■ Manufacturer's Installation instructions
pressure setting.
■ Local Gas Fitting Regulations
■ Municipal Building Codes
An arrow on the base of the regulator
■ Refer to AS/NZS 5601.1 for Gas Installations
indicates the direction of gas flow when the
■ S.A.A. Wiring Code
inlet and outlet of the regulator is orientated
■ Local Electrical Regulations
■ Any other statutory regulations
correctly. When the regulator has been fitted
Preparing to install
check for leaks from the connections with
Refer to AS/NZS 5601.1 for piping size details. These built-in cooktops are intended to
soapy water.
be inserted in a benchtop cutout. Only an officially authorised technician should
connect the appliance. Before you begin, turn off the gas and electricity supply.
Figure 7
Natural gas connection
115
pressure test point
A full operational test and a test for possible leakages must be
carried out by the fitter after installation.
CHECKING THE GAS SUPPLY
• Check the manometer zero point is correct.
• Connect the manometer to the cooktop
pressure point. This is located on the
regulator.
• Turn on the gas supply and electricity and
try to ignite the gas.
NOTE: It will take additional time to light the
gas for the first time as air needs to be purged
from the pipes.
With the appliance operating check the outlet
pressure:
• When all burners of the appliance are
operating at maximum,
• When the smallest burner of the appliance
is operating at minimum.
Under these conditions the outlet pressure
should not vary from the nominal outlet
pressure
of 1.00kPa by more than ±0.20kPa.
If the regulator appears to not be performing
satisfactorily, then check the following points:
• If the outlet pressure is consistently too low
then the inlet pressure may be too low and
adjustment of an upstream regulator may
be needed, or an upstream regulator or
valve
with insufficient flow capacity may be
present in the gas supply line. If this is
suspected
LPG gas connection
95
pressure test point
20

Advertisement

Table of Contents
loading

This manual is also suitable for:

Icgg604wIcgg755wIcgg905w

Table of Contents