OPERATION ON N.G./S.N.G
This appliance is supplied for use with Natural
Gas. However, it can be converted for use with
LPG. Refer to LPG Conversion on page 22.
SUPPLY PIPE SIZING
The total hourly gas consumption for the
appliance is shown on the data label. The
required supply pressure (i.e. at inlet to
appliance regulator) for each gas type is
shown on the data label, and given in Table 3
(page 21). Use this information in conjunction
with the length of run, number of elbows, tees
and bends, the available service pressure and
the supply requirements of other installed
appliances to determine a suitable pipe size.
For assistance in this matter refer to the
appropriate section of AS/NZS 5601.1 or
AS/NZS 5601.2.
An AGA certified class B or D flexible
connection may be used to connect the
cooktop in accordance with AS/NZS 5601.1, in
particular section 5.9 and clause 6.10.1.8, or
AS/NZS 5601.2, in particular section 2.11.
Where a hose assembly is used and the
cooktop is in the installed position, the hose
assembly shall be suitable for connection to a
fixed consumer piping outlet located at a point
800 – 850mm above the floor and in the
region outside the width of the appliance to a
distance of 250mm. The point of connection
to consumer piping must be accessible with
appliance installed.
ELBOW POSITIONING
It is possible to reposition the elbow if
required by loosening the locking nut and
elbow by using two spanners. Re-tighten the
entire assembly after the elbow has been
repositioned. When fitting elbow to appliance,
ensure that the sealing washer is fitted.
Note to Installer: Assembly of elbow to
manifold at rear of unit requires two spanners
to secure locking nut and ensure leak free
connection. For this reason the elbow is
best secured onto cooktop manifold before
installing unit into benchtop.
REGULATOR
An appliance regulator is provided. The
regulator must be positioned so that the
pressure test nipple is accessible when the
appliance is installed.
Connect the gas supply to the ½" B.S.P.
internal thread inlet of the regulator. Refer
to 'bench cutout' Figure 5A–5D (relevant to
your model) for connection point position.
Regulators are supplied pre-adjusted and
configured by the component maker for use
with Natural Gas.
The appliance installer is not required to make
an adjustment to obtain the correct outlet
pressure setting.
An arrow on the base of the regulator
indicates the direction of gas flow when the
inlet and outlet of the regulator is orientated
correctly.
When the regulator has been fitted check for
leaks from the connections with soapy water.