White Link - L.B. White Premier Owner's Manual And Instructions

Ductable heaters
Table of Contents

Advertisement

Available languages

Available languages

10
Premier Ductable Heaters
turns the heater on and off within a temperature
differential of ±3°F (±1.5 °C).
14. Take time to understand how to operate and
maintain the heater by using this Owner's Manual.
Make sure you know how to shut off the gas supply
to the building and also to the individual heater.
Contact your fuel gas supplier if you have any
questions.
15. Any defects found in performing any of the service
or maintenance procedures must be eliminated and
defective parts replaced immediately. The heater
must be retested by properly qualified service
personnel before placing the heater back into use.
Gas Supply Sizing
The vaporization of propane is affected by several
factors: the surface area of the container, the liquid
level of propane, temperature surrounding the
container, and the relative humidity. All of these factors
are specific to a site. Therefore, a degree of
experience and judgement is required to select the
proper propane supply.
Although experience is the best guide, the following
recommendations can be used as a starting point.
The table is based on experience in northern climates
where cold weather and high humidity are prevalent in
the winter. If more or less favorable conditions prevail
at a specific site, adjustments can be made on the
basis of experience.
Recommended Gas Supply
TANK SIZE
500 gal. / 1892 litre
1000 gal. / 3784 litre
If more than one gas supply container is used per
heater, the containers must be manifolded together to
allow vapor withdrawal simultaneously from multiple
containers. Manifold system shall be in accordance
with NFPA 58 or CSA B149.1.
Owner's Manual • Premier 350 2.0
Connecting Hose to
Heater
1. Thread swivel onto connector at gas inlet of heater. See
2. The hose may be coiled up and hung on the hose hanger,
FIG. 1
(Sold separately, 500-133225)
The Premier 350DF 2.0 is factory configured to be
L.B. White LINK Ready.
HEATERS / TANK
For more information on the L.B. White LINK system,
1
contact your local L.B. White Dealer. You may also
call the L.B. White Company, LLC at 1-800-345-7200.
2
Fig. 1. Tighten securely.
with the regulator stored within the regulator storage
bracket.
SWIVEL

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cs350 2.0

Table of Contents